The balancing valve is a special function valve with good flow characteristics, valve opening indication, opening locking device and pressure measuring small valve for flow measurement. Using a special intelligent meter, input the valve type and opening value, and directly display the flow value flowing through the balancing valve according to the measured differential pressure signal. As long as the balance valve of the appropriate specification is installed in each branch and user inlet, And with a dedicated smart meter for one-time debugging, the traffic of each user can reach the set value.
The balance valve is a valve that adjusts dynamic and static balance under hydraulic conditions. Static balance valve, also known as balance valve, manual balance valve, digital lock balance valve, double position control valve, etc., it changes the flow resistance through the valve to change the gap between the valve core and the valve seat (opening) The purpose of the flow, the object of which is the resistance of the system, can balance the new water quantity according to the proportion of the design calculation, and the branches will increase and decrease at the same time, still satisfying the flow demand of the partial load under the current climate demand. The role of heat balance. The dynamic balancing valve is divided into a dynamic flow balancing valve, a self-operating self-pressure differential control valve, and the like.
Dynamic flow balancing valves are also known as self-operated flow control valves, self-operated balancing valves, constant flow valves, and automatic balancing valves. The self-operated flow control valve automatically changes the resistance coefficient according to the change of the operating conditions of the system. Within a certain pressure difference range, the flow rate can be effectively controlled to maintain a constant value, that is, when the differential pressure before and after the valve increases, The automatic closing action of the valve can keep the flow rate from increasing. Conversely, when the pressure difference is reduced, the valve automatically opens and the flow rate remains constant, but when the pressure difference is less than or greater than the normal working range of the valve, it is after all Additional heads are not available, and the flow is still lower or higher than the set flow rate when the valve is fully open or fully closed.
October 09, 2024
September 24, 2024
Envoyer à ce fournisseur
October 09, 2024
September 24, 2024
May 14, 2024
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.